     Daily maintenance content :

1 day class on a pre-filter before checking the automatic drain valve.

2 Check for tower, regeneration and boost the movement is normal .

3 Check the operating conditions , inlet pressure , inlet temperature and air flow .

4 Check the moisture indicator , dried blue , pink represents humid.

5 Check whether the muffler fouling , regeneration tower represents excessive pressure back to red muffler need of replacement.

6 Check the pre-filter and post- filter pressure drop , if the pressure drop exceeds 0.5bar, replace the filter .

Back to top

Monthly maintenance content :

1 Check the heat and there is no heat regeneration dryer control air passing through the filter . Replace if necessary.

2 Check the blower dryer oriented filters filter, replace if necessary .

3 Check the blower dryer suction filter , replace if necessary .

Back to top

Quarterly maintenance content :

1 Check the front and rear filter, check the blockage and possible damage, replace as needed .

2 purge valve with compressed air .

3 Check the output state of the dew point .

Back to top

Annual maintenance content :

1 Close the connection dryer inlet / outlet as valves fully open bypass pipe , completely buck the dryer system , open the desiccant filling mouth, sampling inspection desiccant, desiccant by oil pollution and if crushed , replace desiccant.

(2) Remove and inspect the outlet check valve . Repair and replacement according to the situation .

3 Remove and inspect imported pneumatic valve and the exhaust valve regeneration , cleaning and replacing worn seats and seals.

4 Check for leaks or pneumatic valve cylinder seals for wear .

5 . Maintenance checks boost valves.

6 . Maintenance check control gas solenoid valve.

7 Calibration dew point probe ( if equipped with a dew point meter ) .

8 Check the muffler is clogged by oil or dust , back pressure than 0.35bar should be replaced.

Back to top

Note:

Maintenance on the dryer , please carefully read the instruction manual random


0
Regenerative dryers Maintenance Guide
Regenerative dryers Maintenance Guide
Long by picture save/share
文章推荐

Need more help?

Taigang Iron and Steel Machinery Support Technical Service Let you know more about air compressors, screw compressors and high pressure compressors

online form

  • name

  • phone

  • E-Mail

submit

Security Code
Refresh the code
Cancel
Confirm

business phone:13301650740      Technical Support:13301650740      Address: 1601L2, Hengfang Science and Technology Building, No. 4008, Xinhu Road, Yongfeng Community, Xixiang Street, Baoan District, Shenzhen        粤ICP备12001759号

Business Tel: 13301650740 

Technical support: 13301650740

Company address: 1601L2, Hengfang Science and Technology Building, No. 4008, Xinhu Road, Yongfeng Community, Xixiang Street, Baoan District, Shenzhen  

粤ICP备12001759号

Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.